21
local category.
* If you want to block the access code 048, do the following: 55 + 0 + 0 + 048. when
the caller press 0 + CARRIER CODE + 48, the PABX will block the call.
* To totally block access code 0900, enter in PABX Programming mode and press 55
+ 0 + 0 + 0900.
*
To release all DDD access codes, enter in PABX programmimg mode and press 55
+ 8 + 0. This will block all access code for extensions with local and regional access
and release those for DDD and IDD.
2.7.1 Analyzing the access code table
Factory setting : The PABX analyses the table for all the lines.
This program setting will allow you to determine if the PABX should or should not
analyse the access code table, defyning the extension category to access a
predetermined access code. If the PABX is set not to analyse the table, the calls
will be made as per the category for external calls programmed for each
extensions.
Setting the PABX not to analyze the access code table
Lift handset, press
+
MAIN PA
+
LINE +
, wait for
confirmation tone.
Setting the PABX to analyze the access code table
Lift handset, press
+
MAIN PASSWORD +
+
LINE +
, wait for
confirmation tone.
2.8 Analyzing local numbers digits
Factory setting : Analyze local digits equal to 8.
The non limit of the digits is interesting when the PABX is connected as sub-system of
another PABX.
See the possible types of external calls that can be analyzed :
IDD
(International direct dial ) -
20 numbers
;
DDD
(domestic direct dial ) -
13 numbers
;
CDD
(Collect call direct dial ) -
14 numbers
;
LOCAL
(local dial )
7, 8 or 9 numbers
,
as per the following:
Setting the PABX not to analyze the local digits
Lift handset, press
+
MAIN PA
+
LINE +
, wait for
confirmation tone.
This setting allow
the PABX to analyse
or not the number
of digits pressed to
make an external
call.
LINE:
press 1, 2, 3
or 4, as per the line
you wish to
program, or 9 to
program all the
lines at once.