Development Tools User’s Guide
179
Intel
®
IXP2400/IXP2800 Network Processors
Performance Monitoring Unit
Figure 59. Time-Based Sampling Property Page
Table 4. TBS Property Page Entries and Buttons
Type
Description
Output File
The
Output File
field is used to select where the sampled data file should be placed.
The
Browse…
button exposes available filters to supported file formats.
Selected Macros
The
Selected Macros
text box displays a list of sampling macros selected by the user.
Window (
µ
s)
A
Window
is used to specify the amount of time that performance counters are
enabled. The counters are issued START commands at the beginning of the window. A
STOP command is issued at the end of the window, where the value is then sampled.
Point Sampling
mode is enabled if the
Window
is set to zero. In this mode, samples are
taken every
Period
.
This value is expressed in microseconds.
Period (
µ
s)
The
Period
is used to control the amount of time delay between samples, or STOP
commands.
Samples
Number of samples to be taken.
Start Delay (s)
A start delay value greater than zero has the same effect as waiting the given number
of seconds before pressing the
Run
button.
Max Run Time (s)
Sampling is concluded after the
Max Run Time.
Ring 0 Control
Not supported.
Minimize
This will minimize the PMU window during the run.