Appendix A Parameter Table
- 69 -
Param.
No.
Param. Name
Setting Range
Default
Property
F4-33 AI curve selection
Ones: AI1 curve selection
1: Curve 1 (2 points, see F4-13 to F4-16)
2: Curve 2 (2 points, see F4-18 to F4-21)
3: Curve 3 (2 points, see F4-23 to F4-26)
4: Curve 4 (4 points, see A6-00 to A6-07)
5: Curve 5 (4 points, see A6-08 to A6-15)
Tens: AI2 curve selection, same as AI1
Hundreds: Reserved
321
☆
F4-34 Setting for AI less
than minimum input
Ones: Setting for AI1 less than minimum
input
0: Corresponding percentage of minimum
input
1: 0.0%
Tens: Setting for AI2 less than minimum
input, same as AI1
Hundreds: Reserved
0
☆
F4-35 DI1 delay
0.0s to 3600.0s
0.0s
☆
F4-36 DI2 delay
0.0s to 3600.0s
0.0s
☆
F4-37 DI3 delay
0.0s to 3600.0s
0.0s
☆
F4-38 DI active mode selec-
tion 1
0: High level active
1: Low level active
Ones: DI1
Tens: DI2
Hundreds: DI3
Thousands: DI4
Ten thousands: DI5
0:
★
F4-39 DI active mode selec-
tion 2
0: High level active
1: Low level active
Ones: DI1
Tens: DI2
Hundreds: DI3
Thousands: DI4
Ten thousands: DI5
0:
★
F4-40 AI input type
0: Voltage input
1: Current input (input impedance 500 Ω)
1: Current input (input impedance 250 Ω)
0
★
F4-41 DIO terminal type
Ones: DIO1 type
0: DI/Pulse
1: DO
Tens: DIO2 type
0: DI
1: DO/FMP
00
★
Group F5: Output Terminals
F5-00 DIO2 terminal output
mode
0: Pulse output (FMP)
1: Switch output (FMR)
0
☆