Appendix A Parameter Table
- 96 -
Param.
No.
Param. Name
Setting Range
Default
Property
A8-12 Temperature at stop
0 to 200℃
110℃
☆
A8-13 Pre-warning tempera-
ture
0 to 200℃
105℃
☆
A8-14 Wakeup time
0 to 100s
0s
☆
A8-15 Preparation time
before stop
0 to 100s
20s
☆
A8-16 Lock time at stop
0 to 100s
20s
☆
A8-17 Constant temperature
setting value
0 to 200℃
80℃
☆
A8-18 Fan stop temperature
0 to 200℃
75℃
☆
A8-19 Fan startup tempera-
ture
0 to 200℃
85℃
☆
A8-20 Pre-operation fre-
quency
0.00 Hz to 155.00 Hz
60.00 Hz
☆
A8-21 Pre-operation time
0 to 9999s
10s
☆
A8-22 Hibernating judg-
ment time
0 to 9999s
20s
☆
A8-23
Air filter maintenance
setting time
0 to 65535h
2000h
☆
A8-24
Oil filter maintenance
setting time
0 to 65535h
2000h
☆
A8-25
Oil gas separating
maintenance setting
time
0 to 65535h
2000h
☆
A8-26
Motor lubricating
grease maintenance
setting time
0 to 65535h
2000h
☆
A8-27 Lubricant mainte-
nance setting time
0 to 65535h
2000h
☆
A8-28
Air filter running time
0 to 65535h
0h
☆
A8-29
Oil filter running time
0 to 65535h
0h
☆
A8-30 Oil gas separating
running time
0 to 65535h
0h
☆
A8-31 Motor lubricating
grease running time 0 to 65535h
0h
☆
A8-32 Lubricating oil apply-
ing time
0 to 65535h
0h
☆
A8-33 Hibernating pressure
setting value
0.00 Mpa to 3.50 Mpa
0.75 Mpa
☆
A8-34
Hibernating judg-
ment time upon
unloading
0 to 9999s
5s
☆