Appendix A Parameter Table
- 101 -
Param.
No.
Param. Name
Setting Range
Default
Property
A9-28
Minimum carrier
frequency of synchro-
nous motor in SVC
mode
0.8 kHz to F0-15 (Carrier frequency)
2.0 kHz
☆
A9-29
Synchronous motor
excitation current t
low-speed running
0% to 80%
30%
☆
A9-35 1st fault subcode
0 to 65535
0:
●
A9-36 2nd fault subcode
0 to 65535
0:
●
A9-37 3rd fault subcode
0 to 65535
0:
●
Group AC: AI/AO Correction
AC-00 AI1 measured voltage 1
-10.000 V to +10.000 V
Factory-cor-
rected
☆
AC-01 AI1 displayed voltage 1
-10.000 V to +10.000 V
Factory-cor-
rected
☆
AC-02 AI1 measured voltage 2
-10.000 V to +10.000 V
Factory-cor-
rected
☆
AC-03 AI1 displayed voltage 2
-10.000 V to +10.000 V
Factory-cor-
rected
☆
AC-04 AI2 measured voltage
1 (P2+/P2-)
-10.000 V to +10.000 V
Factory-cor-
rected
☆
AC-05 AI2 displayed voltage
1 (P2+/P2-)
-10.000 V to +10.000 V
Factory-cor-
rected
☆
AC-06 AI2 measured voltage
2 (P2+/P2-)
-10.000 V to +10.000 V
Factory-cor-
rected
☆
AC-07 AI2 displayed voltage
2 (P2+/P2-)
-10.000 V to +10.000 V
Factory-cor-
rected
☆
AC-08 AI3 measured voltage
1 (P1+/P1-)
-10.000 V to +10.000 V
Factory-cor-
rected
☆
AC-09 AI3 displayed voltage
1 (P1+/P1-)
-10.000 V to +10.000 V
Factory-cor-
rected
☆
AC-10 AI3 measured voltage
2 (P1+/P1-)
-10.000 V to +10.000 V
Factory-cor-
rected
☆
AC-11 AI3 displayed voltage
2 (P1+/P1-)
-10.000 V to +10.000 V
Factory-cor-
rected
☆
AC-12 AO1 measured volt-
age 1
-10.000 V to +10.000 V
Factory-cor-
rected
☆
AC-13 AO1 target voltage 1
-10.000 V to +10.000 V
Factory-cor-
rected
☆
AC-14 AO1 measured volt-
age 2
-10.000 V to +10.000 V
Factory-cor-
rected
☆
AC-15 AO1 target voltage 2
-10.000 V to +10.000 V
Factory-cor-
rected
☆
AC-20 PT100 measured volt-
age 1
-3.300 V to +3.300 V
Factory-cor-
rected
☆
AC-21 PT100 target voltage 1
-3.300 V to +3.300 V
Factory-cor-
rected
☆