Appendix A Parameter Table
- 95 -
Param.
No.
Param. Name
Setting Range
Default
Property
A6-14 AI curve 5 maximum
input
A6-12 (AI curve 5 inflection 2 input) to
+10.00V
10.00 V
☆
A6-15
Corresponding per-
centage of AI curve 5
maximum input
-100.0% to +100.0%
100.0%
☆
A6-16 AI1 gain
-10.00 to +10.00
1.00
☆
A6-17
AI1 zero offset coeffi
-
cient
-100.0% to +100.0%
0.0%
☆
A6-18 AI2 gain
-10.00 to +10.00
1.00
☆
A6-19
AI2 zero offset coeffi
-
cient
-100.0% to +100.0%
0.0%
☆
A6-24
Jump point of AI1
input corresponding
setting
-100.0% to 100.0%
0.0%
☆
A6-25
Jump amplitude of
AI1 input correspond-
ing setting
0.0% to 100.0%
0.5%
☆
A6-26
Jump point of AI2
input corresponding
setting
-100.0% to 100.0%
0.0%
☆
A6-27
Jump amplitude of
AI2 input correspond-
ing setting
0.0% to 100.0%
0.5%
☆
Group A8: Air Compressor Control Parameters
A8-00 Test mode
0: Normal mode
1: Tooling test mode
2: Manual unloading mode 1
3: Manual unloading mode 2
0
☆
A8-01 Loading delay
0s to 100s
8s
☆
A8-02 Pre-warning delay
0 to 65535h
0h
☆
A8-03 Pressure sensor func-
tion
0: AI3 as the pressure source
1: AI2 as the pressure source
0
☆
A8-04 Temperature sensor
function
0: Temperature sensor as sensor 1
1: Temperature sensor as sensor 2
0
☆
A8-05 Pressure sensor mea-
suring range
0.10 Mpa to 3.50 Mpa
1.60 Mpa
☆
A8-07 Constant pressure
setting value
0.00 Mpa to 1.60 Mpa
0.70 Mpa
☆
A8-08 Unloading pressure
setting value
0.00 Mpa to 1.60 Mpa
0.80 Mpa
☆
A8-09 Wakeup pressure
(with-load)
0.00 Mpa to 1.60 Mpa
0.60 Mpa
☆
A8-10
Stop pressure setting
value (protection
pressure)
0.00 Mpa to 1.60 Mpa
0.90 Mpa
☆
A8-11 Pre-warning pressure
setting value
0.00 Mpa to 1.60 Mpa
0.85 Mpa
☆