Page 33
EN
Chapter 6 Installation
6.4 Installing the mixing coil
1. Open the eccentric lock on the motor and move it
away to the side.
2. Push the mixing coil into the mixing zone.
3. Then move the motor back again and close the eccen-
tric lock. Ensure that the mixing coil is connected to
the motor and rotor of the pump unit via the motor
bracket.
6.5 Connecting the electrical control system
1. Connect the mixing pump only to regulation construc-
tion site power distribution points with FI circuit breakers
(30 mA).
2. The connection must be fused with 25 A at least.
3. The cross-section of the supply cable is at least 4.0 mm
2
at 400 V 3 PH
4. Connect the supply cable to the feed-in connector of the
switching cabinet.
5. Turn the main switch to vertical (= ON)
5-pole power supply plug
6.6 Mounting the pump unit (rotor / stator / pressure
gauge)
1. To do this, fold the mixing zone upwards and lock it in
place by engaging the fastening lever (1).
2. Mount the pump unit and tighten the two nuts with a
spanner (2).
1
2
NOTE
The machine can be equipped with differ-
ent rotors/stators. Make sure that the pump unit is
mounted centred on the mixing zone.
6.7 Installing the star feeder
1. Before working on the star feeder, interrupt the power
supply (main switch off).
2. Pull out the mains plug.
3. Secure the machine against unexpectedly being
switched back on.
4. Loosen the screw of the protective grating and remove
the protective grating from the material hopper.
5. Then place the star feeder on the centring cone (1) of
the machine. Make sure that the centring pin (2) en-
gages on the star feeder.
6. Screw on the flange nut (3) by hand and tighten it with
a suitable tool.
7. Secure the guard plate (4) with the two locking pins (5).
8. Mount the protective grating on the material hopper
and fix it with the screw (6)