![InoTec inoCOMB Maxi Power Original Operating Manual Download Page 9](http://html1.mh-extra.com/html/inotec/inocomb-maxi-power/inocomb-maxi-power_original-operating-manual_2064543009.webp)
Page 9
EN
Chapter 3 Technical data
2.4 Personnel qualification
Inotec offers training sessions on operating the inoCOMB
Maxi Power. Use INOTEC service for the initial commis-
sioning of the machine; this also serves as an opportunity
to provide operators with training on how to operate the
mixer.
!
DANGER
If the inoCOMB Maxi Power is operated
by unqualified individuals, this could put the life and
health of the operating staff at risk and cause prop-
erty damage to the inoCOMB Maxi Power or other
assets.
2.5 Responsibility of the operator
• Only task trained or instructed staff with operating the
inoCOMB Maxi Power.
• Define employees’ responsibilities for operating, setting
up, maintaining and servicing the machine clearly.
• Only task untrained staff or individuals who have not re-
ceived any instruction with operating the machine when
there is a trained or instructed specialist available to su-
pervise them.
• Work on the electronic control system may only be per-
formed by a qualified electrician.
• When using a sprayer, never point it at people or at haz-
ardous objects.
2.6 Personal protective equipment (PPE)
!
CAUTION
PPE – particularly gloves, safety boots,
a safety helmet and safety goggles and respira-
tory protection – must be used. Even though the
inoCOMB Maxi Power mixing pump does not cause
any increased noise pollution, we recommend the use
of hearing protection on the construction site.
3 Technical data
3.1 Rating plate
1
5
4
2
3
Item Component
Value
1
Manufacturer, address and contact
details, CE marking
-
2
Name and type of machine
-
3
Machine’s year of construction
-
4
Machine number
-
5
Technical data
- Voltage
- Current
- Output
400 V
32 A
5.5 kW
You must always state the machine number if you would
like to order spare parts, have any queries or would like
to make a complaint. You will find this information on the
rating plate or on the delivery note.
3.2 Electric control system, pump output, particle size,
weight, dimensions
Mains voltage
400 V, 50 Hz
Mains supply line (CEE plug)
32 A (to be supplied by
customer)
Pump motor power
5.5 kW
Star feeder motor power
0.55 kW
Fuse
min. 25 A
Delivery rate*
approx. 8-50 l/min.
mineral
Delivery range*
up to 50 m
Delivery height*
up to 30 m
external (without compressor) approx. 250 kg
Dimensions:
Length
1,050 mm
Width
720 mm
Height
1,530 mm
* Material-dependent and depending on the consistency of the material –
observe the material manufacturer’s instructions.