Page 16
EN
Chapter 4 Assembly and function
4.5 Connections
4.5.1 Power connections (230 / 400 V)
1
2
3
4
5
230 V connection socket (1) for optional external devices,
400 V attachment plug (2) for the central power supply of
the mixing pump, remote control socket with dummy plug
(3), plug for the pump motor (4) and socket for the com-
pressor (5).
4.5.2 Water fitting connections
1
2
Connection for an external cleaning hose or con-
nection of the conveyor hose via a coupling piece
for cleaning the hose by means of a sponge ball (1),
connection of the external water supply (2).
4.6 Operating modes
The inoCOMB Maxi Power can be fed with powdery mate-
rial from bags, one-way containers (with the dry conveying
unit inoFLEX Mono), big bags (with the Big-Bag-Box Mono)
or silos (with a conveyor system).
Material loading of a mixing pump from a Big-Bag-Box
Mono with the inoFLEX Mono dry conveying unit.