Page 14
EN
Chapter 4 Assembly and function
1
2
3
Side view of switching cabinet
Description of the displays, controls and connections
Item
Component
1
Socket 230 V
2
CEE surface-mounted plug 5 x 32 A
3
Remote control socket
4.4.2 Mixing pump unit (motor, mixing coil, rotor/sta-
tor and mortar pressure gauge)
The mixing coil is connected to the motor via the drive shaft
and rotates during operation in the mixing zone. The mixing
coil is also connected to the rotor via a plug-in connection.
The mixing coil can be pulled out for cleaning and mainte-
nance work. Before removing the mixing coil, switch off the
machine and pull out the mains plug. The choice of mixing
coil (see accessories) depends on the planned application.
The mortar pressure gauge is used to monitor and display
the pressure in the conveyor hose.
This image illustrates the connection from the motor to
the mixing coil, and from the mixing coil to (rotor/stator).
Power is supplied to the motor via a plug-in connection to
the machine’s switching cabinet.
!
DANGER
Rotating mixing shafts.
Danger of death due to being pulled into the ma-
chine and crushed.
When the motor is running, the mixing shaft rotates
in the mixing zone!
• Do not reach into the rotating mixing shaft.
• Do not place any objects into the rotating mixing shaft.
1. Before working on the metering and mixing shaft, inter-
rupt the external power supply (main switch off).
2. Pull out the mains plug.
3. Secure the machine against unexpectedly being switched
back on.
4. Open the eccentric lock on the motor and move it away
to the side.
4.4.3 Water fitting
1
2
3 4
5
6
7
8 10
9
11
12