3 Building the data set
The Input/Output Configuration panel displays.
1. Select
Options
from the action bar.
2. Select
Build data set
from the pull-down.
The Build Configuration Data Set panel
displays.
3. Select
Ignore unrecognized card
statements
if there are MVSCP statements
in addition to IOCP statements.
4. If you want to build the data set for LPAR
mode, select
Build the IOCDS for
Logically partitioned mode
5. Select
OK
The Confirm the Action panel displays.
(This panel only displays the first time a
build is requested.)
6. Select
Ok
A Configuration Task in Progress panel
displays while the IOCP program is run.
The IOCP program may take up to 12
minutes to complete. When complete, a
message displays confirming the function is
complete.
7. Select
OK
.
8. Select
Options
from the action bar.
9. Select
Exit
from the pull-down.
6-48
Installing the System