204
reboot
: Specifies that when a software exception occurs on an MPU, the switch automatically reboots the
MPU to recover it from the error condition.
Description
Use the
system-failure
command to configure the software exception handling method for MPUs.
By default, an MPU reboots to recover from a software exception condition.
In an IRF fabric, the software exception handling method applies to all member switches.
NOTE:
An LPU always reboots to recover from a software exception condition.
Examples
# Set the software exception handling method to reboot for MPUs.
<Sysname> system-view
[Sysname] system-failure reboot
temperature-limit
Syntax
In standalone mode:
temperature-limit
slot
slot-number
hotspot
sensor-number
lowerlimit warninglimit
[
alarmlimit
]
undo temperature-limit slot
slot-number
hotspot
sensor-number
In IRF mode:
temperature-limit
chassis
chassis-number
slot
slot-number
hotspot
sensor-number
lowerlimit
warninglimit
[
alarmlimit
]
undo temperature-limit chassis
chassis-number
slot
slot-number
hotspot
sensor-number
View
System view
Default level
2: System level
Parameters
chassis
chassis-number
: Specifies an IRF member switch. The
chassis-number
argument represents the IRF
member ID of the switch. (In IRF mode)
slot
slot-number
: Specifies a card in the specified switch. The
slot-number
argument represents the slot
number of the card.
hotspot
: Specifies a hotspot sensor. Hotspot sensors are placed near major heat sources, for example,
chips, to monitor their temperature.
sensor-number
: Specifies a sensor number, an integer that increases from 1.
lowerlimit
: Low temperature threshold in Celsius degrees. The value ranges from –5°C to +5°C (23°F to
41°F).
Summary of Contents for A7500 Series
Page 7: ...v Index 210 ...