183
Table 31
Output description
Field Description
transceiver diagnostic information
Digital diagnosis information of the transceiver plugged in
the interface
Current diagnostic parameters
Current diagnostic parameters
Temp.(°C)
Digital diagnosis parameter-temperature, in °C, with the
precision to 1°C.
Voltage(V)
Digital diagnosis parameter-voltage, in V, with the
precision to 0.01 V.
Bias(mA)
Digital diagnosis parameter-bias current, in mA, with the
precision to 0.01 mA.
RX power(dBm)
Digital diagnosis parameter-RX power, in dBm, with the
precision to 0.01 dBm.
TX power(dBm)
Digital diagnosis parameter-TX power, in dBm, with the
precision to 0.01 dBm.
display transceiver manuinfo
Syntax
display transceiver manuinfo
interface
[
interface-type interface-number
] [
|
{
begin
|
exclude
|
include
}
regular-expression
]
View
Any view
Default level
2: System level
Parameters
interface
[
interface-type interface-number
]: Displays the electronic label data for the transceiver module
in the specified interface or all transceiver modules. The
interface-type interface-number
arguments
specify an interface by its type and number.
|
: Filters command output by specifying a regular expression. For more information about regular
expressions, see
Fundamentals Configuration Guide
.
begin
: Displays the first line that matches the specified regular expression and all lines that follow.
exclude
: Displays all lines that do not match the specified regular expression.
include
: Displays all lines that match the specified regular expression.
regular-expression
: Specifies a regular expression, a case-sensitive string of 1 to 256 characters.
Description
Use the
display transceiver manuinfo
command to display the electronic label data for transceiver
modules.
Examples
# Display the electronic label data for the transceiver module in interface GigabitEthernet 2/0/4.
<Sysname> display transceiver manuinfo interface gigabitethernet 2/0/4
Summary of Contents for A7500 Series
Page 7: ...v Index 210 ...