168
……Omitted……
display environment
Syntax
In standalone mode:
display environment
[
slot
slot-number
] [
|
{
begin
|
exclude
|
include
}
regular-expression
]
In IRF mode:
display
environment
[
chassis
chassis-number
[
slot
slot-number
] ] [
|
{
begin
|
exclude
|
include
}
regular-expression
]
View
Any view
Default level
1: Monitor level
Parameters
chassis
chassis-number
: Displays temperature information for an IRF member switch. The
chassis-number
argument represents the IRF member ID of the switch. (In IRF mode)
slot
slot-numbe
r: Displays temperature information for a card. The
slot-number
argument represents the
slot number of the card.
|
: Filters command output by specifying a regular expression. For more information about regular
expressions, see
Fundamentals Configuration Guide
.
begin
: Displays the first line that matches the specified regular expression and all lines that follow.
exclude
: Displays all lines that do not match the specified regular expression.
include
: Displays all lines that match the specified regular expression.
regular-expression
: Specifies a regular expression, a case-sensitive string of 1 to 256 characters.
Description
Use the
display environment
command to display temperature information, including the current
temperature and temperature thresholds.
In standalone mode, if no card is specified, this command displays the current temperature and
temperature settings for all cards.
In IRF mode, if no member switch is specified, this command displays temperature information for all
member switches. If a member switch is specified but no card is specified, this command displays
temperature information for the specified switch. If a card is specified, this command displays
temperature information for the specified card.
Related commands:
temperature-limit
.
Examples
# In standalone mode, display temperature information.
<Sysname> display environment
System temperature information (degree centigrade):
----------------------------------------------------------------------
Slot Sensor Temperature Lower Warning Alarm Shutdown
Summary of Contents for A7500 Series
Page 7: ...v Index 210 ...