191
Description
Use the
mmu-monitor enable
command to enable automatic data recovery for the expansion memory on
an LSQ1SRP1CB MPU.
Use the
undo mmu-monitor enable
command to disable the function.
By default, the data recovery function is enabled for the LSQ1SRP1CB MPU.
When data error occurs on the specified card, this function can automatically recover the data.
Examples
# Disable data recovery for the expansion memory on the LSQ1SRP1CB MPU in slot 1.
<Sysname> system-view
System View: return to User View with Ctrl+Z.
[Sysname] undo mmu-monitor enable 1
oem hp
Syntax
In standalone mode:
oem hp
[
slot
slot-number
]
In IRF mode:
oem hp
[
chassis
chassis-number
slot
slot-number
]
View
User view
Default level
2: System level
Parameters
slot
slot-number
: Specifies the slot number of a card. If no card is specified, the command applies to all
IRF member switches. (In standalone mode)
chassis
chassis-number
slot
slot-number
: Specifies a card in an IRF member switch. The
chassis-number
argument represents the IRF member ID of the switch and the
slot-number
argument represents the slot
number of the card. If no card is specified, the command applies to all IRF member switches. (In IRF
mode)
Description
Use the
oem hp
command to enable brand migration for H3C MPUs to migrate to HP MPUs.
After you perform this command, use the
display oem
command to verify the new brand name and
reboot the switch.
Perform brand migration immediately after you set up a switch or IRF fabric that has both H3C and HP
MPUs. The migration prevents network management software, for example, IMC, from mistakenly
identifying the following events as a device replacement:
•
On a standalone switch, active/standby switchover occurs between the H3C and HP MPUs.
•
In an IRF fabric, one switch is re-elected as the master but its active MPU has a brand different than
the active MPU on the old master.
Summary of Contents for A7500 Series
Page 7: ...v Index 210 ...