190
undo monitor handshake-timeout disable-port
View
System view
Default level
2: System level
Parameters
None
Description
Use the
monitor handshake-timeout disable-port
command to enable the port-down function.
Use the
undo monitor handshake-timeout disable-port
command to disable the port-down function.
The port-down function shuts down all network ports of a standalone switch or an IRF member switch
immediately after all its MPUs are unplugged or reboot abnormally. This function does not work as long
as the switch has an active MPU.
By default, the port-down function is disabled.
Examples
# Enable the port down function globally
<Sysname> system-view
System View: return to User View with Ctrl+Z.
[Sysname] monitor handshake-timeout disable-port
Open port-down function in slot 1 !
Open port-down function in slot 2 !
Open port-down function in slot 3 !
mmu-monitor enable
Syntax
In standalone mode:
mmu-monitor enable slot
slot-number
undo mmu-monitor enable slot
slot-number
In IRF mode:
mmu-monitor enable chassis
chassis-number
slot
slot-number
undo mmu-monitor enable chassis
chassis-number
slot
slot-number
View
System view
Default level
2: System level
Parameters
chassis
chassis-number
: Specifies the member ID of an IRF member switch. (In IRF mode)
slot-number
: Specifies the slot number of an LSQ1SRP1CB MPU.
Summary of Contents for A7500 Series