19.9 Flow meter calibration
In this respect pay attention to the operating instructions of the job computer for the
crop protection sprayer from Müller Elektronik.
19.10 Notes on crop protection sprayer inspection
Sprayer testing must only be carried out by authorized bodies.
Sprayer testing is prescribed by law:
• at the latest 6 months after commissioning
(if not done when purchased), then
• every 4 half years.
Hose connection for pump test (1)
(available from the manufacturer)
Hose connection for flow meter test (2)
(available from the manufacturer)
Pump test - pump capacity test
1. Plug the test hose on the pressure port (3)
(2“ Camloc coupling required)
2. On Commander-Box:
• Circulation "OPEN"
• Agitator, injector and inside cleaning "CLOSED"
Flow meter test
1. Loosen the clamp (4).
2. Testing process
3. Hose connection for flow meter (5)
4. Tighten the clamp (4).
5. Switch on the pump
Pressure gauge test
Screw the test pressure gauge into the
1/4 inch female thread (6)
4
5
1
2
3
6