12.5.2 Flushing in powdery prepa
rations and carbamide
Before spraying completely dissolve the carbamide by
recirculating fluids. When dissolving larger carbamide
quantities the temperature of the wash will drop consid-
erably, this dissolves the carbamide much slower. The
warmer the water, the quick and better the dissolving of
carbamide.
1. Fill the wash container half with water
2. Set the suction side to wash container
3. Open the lid on the illuviation valve
4. Switch on the injector
5. Open the ball valve
6. Switch on the closed circuit line
7. Switch on the shock nozzles
8. Fill the required preparation quantity as
calculated for filling the container into the illuviation
valve (max. 45 l).
9. Close the ball valve again
10. Switch off the injector
11. Adjust the desired agitator power
12. Fill in the missing amount of water
12.5.3 Flushing in with ECOFILL (optional)
1. Fill the wash container half with water
2. Set the suction side to wash container
3. Switch on the injector
4. Connect the ECOFILL coupling (1) to the suction
socket
5. Open the ball valve
6. Draw in the amount of preparation calculated
and measured to fill the container
7. Close the ball valve again
8. Disconnect the ECOFILL coupling (1) and
place it on the flushing foot (2)
9. Close the ball valve again
10. Open the ball valve and flush the ECOFILL valve with
clear water
11. Close the ball valve and remove the ECOFILL valve
12. Switch off the injector
13. Adjust the desired agitator power
14. Fill in the missing amount of water
→
Canister flushing
→
Closed circuit flushing
→
Shock nozzle
→
Washing gun
Switch-over ball valve
→ ECOFILL
OPEN