→ Canister flushing
→ Closed circuit flushing
→ Shock nozzle
→ Washing gun
Switch-over ball valve
→ ECOFILL
OPEN
CLOSE
12.5.4 Pre-cleaning the canister with
wash
1. Set the suction side to fresh water
2. Open the lid on the illuviation valve
3. Switch on the injector on the C-Box
(the spraying pump starts automatically)
4. Open the ball valve
5. Switch on canister flushing
6. Put the canister or any other container over the
canister flushing facility and press it down for at
least 30 seconds.
7. Close the ball valve again
8. Switch off the injector
12.5.5 Pre-cleaning the canister with rins-
ing water
Cleaning the canister with rinsing water dilutes the con-
centration of the wash!
1. Set the suction side to fresh water
2. Open the lid on the illuviation valve
3. Switch on the injector on the C-Box
(the spraying pump starts automatically)
4. Open the ball valve
5. Switch on canister flushing
6. Put the canister or any other container over the
canister flushing facility and press it down for at
least 30 seconds.
7. Close the ball valve again
8. Switch off the injector
Water (wash) emerges from the canister
flushing nozzle, when the pressure plate
is pressed down.