Rev. 1.00
237 of 486
July 31, 2018
32-Bit Arm
®
Cortex
®
-M0+ MCU
HT32F50231/HT32F50241
13 General-Purpose T
imer (GPTM)
Bits
Field
Descriptions
[8]
UEVIF
Update Event Interrupt Flag
This bit is set by hardware on an update event and is cleared by software.
0: No update event occurs
1: Update event occurs
Note: The update event is derived from the following conditions:
- The counter overflows or underflows
- The UEVG bit is asserted
- A restart trigger event occurs from the slave trigger input
[7]
CH3OCF
Channel 3 Over-Capture Flag
This flag is set by hardware and cleared by software.
0: No over-capture event is detected
1: Capture event occurs again when the CH3CCIF bit is already set and it is not
yet cleared by software
[6]
CH2OCF
Channel 2 Over-Capture Flag
This flag is set by hardware and cleared by software.
0: No over-capture event is detected
1: Capture event occurs again when the CH2CCIF bit is already set and it is not
cleared yet by software
[5]
CH1OCF
Channel 1 Over-Capture Flag
This flag is set by hardware and cleared by software.
0: No over-capture event is detected
1: Capture event occurs again when the CH1CCIF bit is already set and it is not
cleared yet by software.
[4]
CH0OCF
Channel 0 Over-Capture Flag
This flag is set by hardware and cleared by software.
0: No over-capture event is detected
1: Capture event occurs again when the CH0CCIFbit is already set and it is not
yet cleared by software.
[3]
CH3CCIF
Channel 3 Capture / Compare Interrupt Flag
- Channel 3 is configured as an output:
0: No match event occurs
1: The contents of the counter CNTR have matched the contents of the CH3CCR
register
This flag is set by hardware when the counter value matches the CH3CCR value
except in the center-aligned mode. It is cleared by software.
- Channel 3 is configured as an input:
0: No input capture occurs
1: Input capture occurs
This bit is set by hardware on a capture event. It is cleared by software or by
reading the CH3CCR register.
[2]
CH2CCIF
Channel 2 Capture / Compare Interrupt Flag
- Channel 2 is configured as an output:
0: No match event occurs
1: The contents of the counter CNTR have matched the contents of the CH2CCR
register
This flag is set by hardware when the counter value matches the CH2CCR value
except in the center-aligned mode. It is cleared by software.
- Channel 2 is configured as an input:
0: No input capture occurs
1: Input capture occurs
This bit is set by hardware on a capture event. It is cleared by software or by
reading the CH2CCR register.