HLP-NV Series
HLP-NV Series
-
45
-
C01.61 High Speed Load Compensation Default setting 100%
Range
[0 - 199 %]
●
Function:
Use this parameter to obtain optimum load compensation
when running at high speed.
Enter percentage to compensate in relation to load when motor runs at
high speed.
Change-over point is automatically calculated based on motor size.
C01.62 Slip Compensation
Default setting 100%
Range
[-400 - 399 %]
●
Function:
Compensation for load dependent motor slip. Slip
compensation is calculated automatically based on rated motor speed,
nM,N.
●
ATTENTION!
This function is only active when par. C01.00,
Configuration Mode, is set to Speed Open Loop [0],and when par.
C01.01, Motor Control Principle, is set to VVC+ [1].
C01.63 Slip Compensation Time Constant Default setting 0.10 s
Range
[0.05 - 5.00 s]
●
Function:
0.10 s [0.05 - 5.00 s] Enter slip compensation reaction speed.
A high value results in slow reaction whereas a low value results in
quick reaction.
If low-frequency resonance problems arise, use longer time setting.