HLP-NV Series
HLP-NV Series
-
102
-
8: Pulse input
C03.15 = 8 Pulse input select
C03.16 = 0
C03.17 = 0
C05.10 = 8 Start command
C05.15 = 32 Pulse input select
C05.55 = 20 Terminal EMS low frequency
C05.56 = 5000 Terminal EMS high frequency
C05.57 = 0 Terminal EMS low value
C05.58 = 50 Terminal EMS high value
C16.68 can be Viewew input frequency on EMS
Press "Auto"”to active Auto mode
Connect RUN with EV to operate the drive.
C03.11 = 10.00Hz(Jog frequency)
C03.15 = 1 C03.16 = 0 C03.17 = 0
C03.41 = 0.5S C03.42 = 0.5S C03.80 = 0.5
C04.10 = 2
C05.10 = 8 C05.11 = 11
C05.13 = 14
C06.10 = 0V C06.11 = 10V
C06.14 = 0Hz C06.15 = 50Hz