9. TROUBLESHOOTING
9-23
Table 9-3 Event log entries unique to the equipment (2/3)
No.
Event
ID
Source
Type
Description
Action
12
525
HFWRAS_SYS
Information In DIMM%1, error
corrections have been
occurring at a high
frequency.
The DIMM might have failed. Contact
your system administrator or
maintenance personnel.
13
539
HFWRAS_SYS
Error
The %1 monitor finished.
Hardware monitoring of the RAS
software has been terminated. If
restarting the equipment does not
resolve the error, contact the system
administrator or maintenance personnel.
14
540
HFWRAS_SYS
Information In DIMM%1, the number
of single-bit errors that
have been corrected since
the OS started is %2
(comparison with last
time: %3).
No action required.
15
541
HFWRAS_SYS
Warning
DIMM%1 might have
failed.
The DIMM might have failed. Contact
the system administrator or maintenance
personnel.
16
769
HFWRAS_APP
Error
An error occurred in %1.
Error code = %2.
An error was generated by the RAS
software while the software was
running. If restarting the equipment does
not resolve the error, contact the system
administrator or maintenance personnel.
17
771
HFWRAS_APP
Error
Because an incorrect value
is specified in the registry
value %1, the default
value %2 is set.
If restarting the equipment does not
resolve the error, contact the system
administrator or maintenance personnel.
18
800
HFWRAS_SYS
Information %1
Detailed code = %2.
A STOP error occurred. Check the error
and contact the system administrator or
maintenance personnel.
19
900
HFWRAS_SYS
Information The power shutdown factor
code is %1.
A power shutdown occurred. Contact
the system administrator or maintenance
personnel.
20
2001
HFWRAS_SYS
Error
The drive in drive bay %1
is offline because of a
failure.
Read the description of abnormal
temperature in 10.4.2 and take action
accordingly.
21
2002
HFWRAS_SYS
Information The RAID status is
optimal.
No action required.
22
2003
HFWRAS_SYS
Error
RAS could not acquire the
RAID status. The RAID
status is unknown.
Contact the system administrator or
maintenance personnel.
23
2004
HFWRAS_SYS
Information The RAID status was
revealed.
No action required.
24
2009
HFWRAS_SYS
Information The drive in drive bay %1
is offline because of
manual operation.
No action required.
Summary of Contents for HF-W2000 50
Page 37: ...C 12 This page is intentionally left blank ...
Page 91: ...2 30 This page is intentionally left blank ...
Page 147: ...This page is intentionally left blank ...
Page 171: ...This page is intentionally left blank ...
Page 183: ...This Page Intentionally Left Blank ...
Page 211: ...This Page Intentionally Left Blank ...