Table 21-14 Control Signal Timing
Condition A: V
CC
= 2.7 V to 5.5 V, AV
CC
= 2.7 V to 5.5 V, V
REF
= 2.7 V to AV
CC
,
V
SS
= AV
SS
= 0 V, ø = 1 MHz to 8 MHz, T
a
= –20°C to +75°C (regular
specifications), T
a
= –40°C to +85°C (wide-range specifications)
Condition C: V
CC
= 5.0 V ± 10%, AV
CC
= 5.0 V ± 10%, V
REF
= 4.5 V to AV
CC
,
V
SS
= AV
SS
= 0 V, ø = 1 MHz to 16 MHz, T
a
= –20°C to +75°C (regular
specifications), T
a
= –40°C to +85°C (wide-range specifications)
Condition A
Condition C
8 MHz
16 MHz
Test
Item
Symbol
Min
Max
Min
Max
Unit
Conditions
RES
setup time
t
RESS
200
—
200
—
ns
Figure 21-18
RES
pulse width
t
RESW
10
—
10
—
t
CYC
Mode programming
t
MDS
200
—
200
—
ns
setup time
RESO
output delay
t
RESD
—
100
—
100
ns
Figure 21-19
time
RESO
output pulse width
t
RESOW
132
—
132
—
t
CYC
NMI setup time
t
NMIS
200
—
150
—
ns
Figure 21-20
(NMI, IRQ
5
to IRQ
0
)
NMI hold time
t
NMIH
10
—
10
—
(NMI, IRQ
5
to IRQ
0
)
Interrupt pulse width
t
NMIW
200
—
200
—
(NMI, IRQ
2
to IRQ
0
when exiting software
standby mode)
Clock oscillator settling
t
OSC1
20
—
20
—
ms
Figure 21-22
time at reset (crystal)
Clock oscillator settling
t
OSC2
7
—
7
—
ms
Figure 20-1
time in software standby
(crystal)
686
www.DataSheet4U.com