For instructions on setting virtual IDs, see the
Hitachi Command Control
Interface Command Reference
.
Related topics
•
GAD and global storage virtualization on page 1-9
Monitoring GAD status
GAD operations are managed based on the following information:
•
Pair status
•
I/O mode of the P-VOL and S-VOL
•
GAD status, which is a combination of pair status and I/O mode
Related topics
•
•
GAD status transitions on page 1-11
•
•
Relationship between GAD status, pair status, and I/O mode on page
•
Global-active device and server I/O on page 1-14
GAD status
The following table lists and describes the GAD statuses.
GAD status
Description
Data
redundancy
Updated
volume
Volume with
latest data*
Simplex
The volume is not a pair volume.
No
Not applicable
Not applicable
Mirroring
The pair is changing to Mirrored status.
This status is issued when you do the
following:
•
Prepare a quorum disk.
•
Copy data from the P-VOL to the
S-VOL.
No
P-VOL and S-
VOL
P-VOL
Mirrored
The pair is operating normally.
Yes
P-VOL and S-
VOL
P-VOL and S-
VOL
Suspended
The pair is suspended. I/O from the
server is sent to the volume with the
latest data.
When a failure occurs or the pair is
suspended, the status changes to
Suspended.
No
P-VOL or S-
VOL
P-VOL or S-
VOL
Blocked
I/O is not accepted by either pair
volume. This status occurs when:
No
None
P-VOL and S-
VOL
1-10
Overview of global-active device
Hitachi Virtual Storage Platform G1000 Global-Active Device User Guide
Summary of Contents for G1000
Page 8: ...Index viii Hitachi Virtual Storage Platform G1000 Global Active Device User Guide ...
Page 14: ...xiv Preface Hitachi Virtual Storage Platform G1000 Global Active Device User Guide ...
Page 238: ...9 18 Troubleshooting Hitachi Virtual Storage Platform G1000 Global Active Device User Guide ...
Page 245: ...Hitachi Virtual Storage Platform G1000 Global Active Device User Guide ...