Shutting down CCI
You must shut down both CCI instances before editing the configuration
definition files.
Procedure (Windows shown)
Shut down instance 0 and instance 1.
horcmshutdown 0 1
inst 0:
HORCM Shutdown inst 0 !!!
inst 1:
HORCM Shutdown inst 1 !!!
Editing CCI configuration definition files
The following examples show the configuration definition files for a Windows
host. Make sure to specify the actual LDEV IDs for the GAD pair volumes, not
the virtual LDEV IDs.
Note:
When specifying the serial number for VSP G1000 using CCI, add a “3”
at the beginning of the serial number. For example, for serial number 11111,
enter 311111.
Example of primary HORCM file, horcm0.conf
The underlined lines below show the updates for the volumes in the sample
configuration in this chapter. Make sure to enter the information for your
system in your configuration definition files.
HORCM_MON
#ip_address service poll(10ms) timeout(10ms)
localhost 31000 -1 3000
HORCM_CMD
\\.\PhysicalDrive0
HORCM_LDEV
#GRP DEV SERIAL LDEV# MU#
oraHA dev1 311111 22:22 0
HORCM_INST
#GPR IP ADR PORT#
oraHA localhost 31001
Example of secondary HORCM file, horcm1.conf
The underlined lines below show the updates for the volumes in the sample
configuration in this chapter. Make sure to enter the information for your
system in your configuration definition files.
HORCM_MON
#ip_address service poll(10ms) timeout(10ms)
4-42
Configuration and pair management using CCI
Hitachi Virtual Storage Platform G1000 Global-Active Device User Guide
Summary of Contents for G1000
Page 8: ...Index viii Hitachi Virtual Storage Platform G1000 Global Active Device User Guide ...
Page 14: ...xiv Preface Hitachi Virtual Storage Platform G1000 Global Active Device User Guide ...
Page 238: ...9 18 Troubleshooting Hitachi Virtual Storage Platform G1000 Global Active Device User Guide ...
Page 245: ...Hitachi Virtual Storage Platform G1000 Global Active Device User Guide ...