
2
.
Resynchronize the pair.
Related topics
•
Pair condition before failure on page 6-7
Recovery procedure for GAD pair suspension due to other failures
A GAD pair might be suspended due to a failure other than those described in
this chapter. Use the following procedure to recover a suspended pair from
other types of failure.
If you are not able to restore the GAD volumes using this procedure, contact
Hitachi Data Systems customer support.
1
.
Recover from the failure.
a
.
Verify that a failure, such as a suspended GAD pair, has occurred, for
example, by checking for SIMs issued by the primary or secondary
storage system.
b
.
When a failure has occurred, identify the failure and perform
troubleshooting according to the failure type to remove the cause of
the failure.
2
.
Resynchronize the GAD pair.
a
.
Check the I/O mode of the P-VOL and the S-VOL of the suspended
GAD pair.
pairdisplay -g oraHA -fxce -IH0
Group PairVol(L/R) (Port#,TID, LU),Seq#,LDEV#.P/S,Status,
Fence, %,P-LDEV# M CTG JID AP EM E-Seq# E-LDEV# R/W
oraHA dev1(L) (CL1-A-0, 0, 0)311111 2222.P-VOL PSUE
NEVER , 100 4444 - - 0 - - - - L/L
oraHA dev1(R) (CL1-C-0, 0, 0)322222 4444.S-VOL PSUE
NEVER , 100 2222 - - 0 - - - - B/B
pairdisplay -g oraHA -fxce -IH1
Group PairVol(L/R) (Port#,TID, LU),Seq#,LDEV#.P/S,Status,
Fence, %,P-LDEV# M CTG JID AP EM E-Seq# E-LDEV# R/W
oraHA dev1(L) (CL1-C-0, 0, 0)322222 4444.S-VOL PSUE
NEVER , 100 2222 - - 0 - - - - B/B
oraHA dev1(R) (CL1-A-0, 0, 0)311111 2222.P-VOL PSUE
NEVER , 100 4444 - - 0 - - - - L/L
b
.
If the I/O mode of the P-VOL is Local, resynchronize the GAD pair at
the primary storage system.
pairresync -g oraHA -IH0
c
.
If the I/O mode of the S-VOL is Local, resynchronize the GAD pair at
the secondary storage system.
pairresync -g oraHA -swaps -IH1
The volume in the primary storage system changes to an S-VOL, and
the volume in the secondary storage system changes to a P-VOL.
d
.
Confirm that the pair status of the P-VOL and the S-VOL of the GAD
pair has changed to PAIR (Mirror (RL)).
Disaster recovery of global-active device
6-47
Hitachi Virtual Storage Platform G1000 Global-Active Device User Guide
Summary of Contents for G1000
Page 8: ...Index viii Hitachi Virtual Storage Platform G1000 Global Active Device User Guide ...
Page 14: ...xiv Preface Hitachi Virtual Storage Platform G1000 Global Active Device User Guide ...
Page 238: ...9 18 Troubleshooting Hitachi Virtual Storage Platform G1000 Global Active Device User Guide ...
Page 245: ...Hitachi Virtual Storage Platform G1000 Global Active Device User Guide ...