Failure location
SIM reference codes
GAD volume
accessible?
1
Primary
system
Secondary
system
P-VOL
S-VOL
3
Path between the
server and the
secondary storage
system
None
(normal)
None
(normal)
Yes
3
No
4
GAD pair volume
P-VOL
3A0XXX
DD1XYY
DFAXXX
DFBXXX
EF9XXX
DD1XYY
No
Yes
2
5
S-VOL
DD1XYY
3A0XXX
DD1XYY
DFAXXX
DFBXXX
EF9XXX
Yes
3
No
6
Pool for GAD pair
4
Pool for P-VOL
622XXX
DD1XYY
DD1XYY
No
Yes
2
7
Pool for S-VOL
DD1XYY
622XXX
DD1XYY
Yes
3
No
8
Path between storage
systems
Remote path from the
primary to secondary
system
2180XX
DD0XYY
DD3XYY
Yes
3
No
9
Remote path from the
secondary to primary
system
DD3XYY
2180XX
DD0XYY
No
Yes
2
10
Storage system
Primary system
Depends on
the failure
type
5
2180XX
DD0XYY
DD3XYY
No
Yes
2
11
Secondary system
2180XX
DD0XYY
DD3XYY
Depends on
the failure
type
5
Yes
3
No
12
Quorum disk
Path between the
primary system and
quorum disk
21D0XX
21D2XX
DD2XYY
DEF0ZZ
EF5XYY
EFD000
FF5XYY
DD2XYY
Yes
3
No
6-4
Disaster recovery of global-active device
Hitachi Virtual Storage Platform G1000 Global-Active Device User Guide
Summary of Contents for G1000
Page 8: ...Index viii Hitachi Virtual Storage Platform G1000 Global Active Device User Guide ...
Page 14: ...xiv Preface Hitachi Virtual Storage Platform G1000 Global Active Device User Guide ...
Page 238: ...9 18 Troubleshooting Hitachi Virtual Storage Platform G1000 Global Active Device User Guide ...
Page 245: ...Hitachi Virtual Storage Platform G1000 Global Active Device User Guide ...