Failure location
SIM reference codes
GAD volume
accessible?
1
Primary
system
Secondary
system
P-VOL
S-VOL
13
Path between the
secondary system and
quorum disk
DD2XYY
21D0XX
21D2XX
DD2XYY
DEF0ZZ
EF5XYY
EFD000
FF5XYY
Yes
3
No
14
Quorum disk
21D0XX
21D2XX
DD2XYY
DEF0ZZ
EF5XYY
EFD000
FF5XYY
21D0XX
21D2XX
DD2XYY
DEF0ZZ
EF5XYY
EFD000
FF5XYY
Yes
3
No
15
External storage
system
21D0XX
21D2XX
DD2XYY
DEF0ZZ
EF5XYY
EFD000
FF5XYY
21D0XX
21D2XX
DD2XYY
DEF0ZZ
EF5XYY
EFD000
FF5XYY
Yes
3
No
Notes:
1
.
Pairs are not suspended and do not become inaccessible for:
¢
Failure in hardware used for redundancy in the VSP G1000, such as HDD, cache, CHA, DKA, and
MPB
¢
Failure in redundant physical paths
2
.
The volume is not accessible if a failure occurs while the S-VOL pair status is COPY, SSUS, or PSUE.
3
.
The volume is not accessible if a failure occurs while the P-VOL pair status is PSUS or PSUE and the
I/O mode is BLOCK.
4
.
A failure occurs due to a full pool for a GAD pair.
5
.
The SIM might not be viewable, depending on the failure (for example, all cache failure, all MP
failure, storage system failure).
Related topics
•
SIMs related to GAD on page 6-6
•
Pair condition and recovery: server failures on page 6-8
•
Pair condition and recovery: path failure between the server and storage
Disaster recovery of global-active device
6-5
Hitachi Virtual Storage Platform G1000 Global-Active Device User Guide
Summary of Contents for G1000
Page 8: ...Index viii Hitachi Virtual Storage Platform G1000 Global Active Device User Guide ...
Page 14: ...xiv Preface Hitachi Virtual Storage Platform G1000 Global Active Device User Guide ...
Page 238: ...9 18 Troubleshooting Hitachi Virtual Storage Platform G1000 Global Active Device User Guide ...
Page 245: ...Hitachi Virtual Storage Platform G1000 Global Active Device User Guide ...