SIM reference
code
Description
DEF0XX
Quorum Disk Blocked
DFAXXX
LDEV blockade(Drive path: Boundary 0/Effect of Drive port
blockade)
DFBXXX
LDEV blockade(Drive path: Boundary 1/Effect of Drive port
blockade)
EF5XYY
Abnormal end of Write processing in External storage system
EF9XXX
LDEV blockade (Effect of drive blockade)
EFD000
External storage system connection device blockade
FF5XYY
Abnormal end of Read processing in External storage system
Related topics
•
•
Resolving failures in multiple locations on page 6-52
Pair condition before failure
The pair status and I/O mode of a GAD pair, the accessibility of the server,
and the storage location of the latest data depend on the status before a
failure occurs.
The following table shows pair status and I/O mode, the volumes accessible
from the server, and the location of the latest data before a failure occurs.
You can compare this information with the changes that take place after a
failure occurs, as described in the following topics.
Pair status and I/O mode
Volume accessible from the
server
Volume with
latest data
P-VOL
S-VOL
P-VOL
S-VOL
PAIR (Mirror
(RL))
PAIR (Mirror
(RL))
OK
OK
Both P-VOL and
S-VOL
COPY (Mirror
(RL))
COPY (Block)
OK
NG
P-VOL
PSUS/PSUE
(Local)
SSUS/PSUE
(Block)
OK
NG
P-VOL
PSUS/PSUE
(Block)
SSWS (Local)
NG
OK
S-VOL
Disaster recovery of global-active device
6-7
Hitachi Virtual Storage Platform G1000 Global-Active Device User Guide
Summary of Contents for G1000
Page 8: ...Index viii Hitachi Virtual Storage Platform G1000 Global Active Device User Guide ...
Page 14: ...xiv Preface Hitachi Virtual Storage Platform G1000 Global Active Device User Guide ...
Page 238: ...9 18 Troubleshooting Hitachi Virtual Storage Platform G1000 Global Active Device User Guide ...
Page 245: ...Hitachi Virtual Storage Platform G1000 Global Active Device User Guide ...