
Contents
i
Contents
Task-Oriented Reference ............................... 1
Measurement Flow......................................... 2
Introduction..................................................... 3
Verifying Package Contents ........................... 3
Safety Information .......................................... 5
Operating Precautions.................................... 7
Product Overview and Features ........ 11
Block Diagram ..........................................14
Names and Functions of Parts ........... 15
Screen Organization .......................... 17
Chapter 2 Measurement
Preparations
Connecting the Power Cord............... 22
Connecting Measurement Cables and
Test Fixtures ...................................... 23
Making Your Own Measurement Cables ..24
Turning the Power On and Off ........... 25
Chapter 3 Measurement
Settings (Basic Measurements)
Pre-Operation Inspection ................... 27
Measurement Object Types ............... 28
Setting the Measurement Speed ....... 29
Setting Measurement Start Conditions
(Trigger Source) ................................. 30
Selecting the Measurement Range .... 31
Zero Adjustment ................................. 32
Judging Measured Values
(Comparator Function) ....................... 34
Decide According to Reference Value and
Tolerance (REF% Mode) ..........................35
Confirming Faulty Measurements ......38
Chapter 4 Customizing
Measurement Settings
Making Range-Specific Measurement
Settings 41
Setting Pre-Measurement Delay ........42
Setting the Measurement Integration
Time Option
Checking for Poor or Improper Contact
(Contact Check Function) ...................46
Improving Probe Contact
(Contact Improver Function) ...............47
Detecting Measurement Voltage Faults
(Voltage Level Monitor Function) .......49
Applying Current Only When Measuring
(Current Mode Setting) .......................50
Test for Short-Circuited Probe
(Probe Short-Circuit Detection Function)
............................................................51
Comparing the Measurement Settings of
Two Instruments
(Settings Monitor Function) ................ 53
4.10 Retrying Measurement After a Fault
(Retry Function) ..................................56
4.11 Maintaining Measurement Precision
(Self-Calibration) ................................57
4.12 Compensating for Thermal EMF Offset
(Offset Voltage Compensation - OVC) 57
Disabling and Enabling Key Operations
59
Disabling Key Operations
(Key-Lock Function) ................................. 59
Re-Enabling Key Operations
(Key-Lock Cancel) ................................... 60
Setting the Comparator Decision and
Key Beepers .......................................61
Enabling or Disabling the Key Beeper ..... 61
1
2
3
4
5
Summary of Contents for RM3542
Page 2: ......
Page 6: ...Contents iv ...
Page 16: ...Operating Precautions 10 ...
Page 26: ...1 3 Screen Organization 20 ...
Page 32: ...2 3 Turning the Power On and Off 26 ...
Page 46: ...3 8 Confirming Faulty Measurements 40 ...
Page 64: ...4 12 Compensating for Thermal EMF Offset Offset Voltage Compensation OVC 58 ...
Page 84: ...6 4 Auto Exporting Measured Values at End of Measurement Data Output Function 78 ...
Page 90: ...7 3 Printing 84 ...
Page 172: ...9 10 Device Compliance Statement 166 ...
Page 190: ...11 4 Disposing of the Instrument 184 ...
Page 200: ...Appendix 5 Dimensional Diagram A10 Appendix 5 Dimensional Diagram ...
Page 214: ...Index Index 4 ...
Page 215: ......
Page 216: ......
Page 217: ......
Page 218: ......