9.7 Message Reference
132
Decision Mode Setting
Syntax
Command
:CALCulate:LIMit:MODE
<ABS/ REF>
Query
Response
:CALCulate:LIMit:MODE?
<ABS/ REF>
<ABS>
= Upper threshold/Lower threshold comparison
<REF>
= Reference percentage/tolerance comparison
Example
:CALC:LIM:MODE REF
Set and Query ABS Mode Upper/Lower Comparator Threshold Values
Syntax
Command
:CALCulate:LIMit:ABS
<Upper threshold>
,
<Lower threshold>
Query
Response
:CALCulate:LIMit:ABS?
<Upper threshold>,<Lower threshold>
<Upper threshold>
= 0 to 120.000E+6 (NRf)
<Lower threshold>
= 0 to 120.000E+6 (NRf)
Example
:CALC:LIM:ABS 1.00035,0.99965
Set and Query REF% Mode Reference Resistance
Syntax
Command
:CALCulate:LIMit:REFerence
<Reference Resistance>
Query
Response
:CALCulate:LIMit:REFerence?
<Reference Resistance>
<Reference Resistance>
= 0 to 120.000E+6 (NRf)
Example
:CALC:LIM:REF 1.2E+3
Set and Query REF% Mode Upper/Lower Comparator Threshold Percentages
Syntax
Command
:CALCulate:LIMit:PERCent
<Upper threshold (%)>
,
<Lower
threshold(%)>
Query
Response
:CALCulate:LIMit:PERCent?
<Upper threshold (%)>,<Lower threshold (%)>
<Upper threshold (%)>
= -99.990 to 99.990 (NR2)
<Lower threshold (%)>
= -99.990 to 99.990 (NR2)
Note
Setting resolution is 0.01% for
±
10.00% or more.
Example
:CALC:LIM:PERC 1.505,-2.005
Queries the comparator result
Syntax
Query
Response
:CALCulate:LIMit:RESult?
<HI/ IN/ LO/ OFF/ ERR>
Example
:CALC:LIM:RES?
HI
Summary of Contents for RM3542
Page 2: ......
Page 6: ...Contents iv ...
Page 16: ...Operating Precautions 10 ...
Page 26: ...1 3 Screen Organization 20 ...
Page 32: ...2 3 Turning the Power On and Off 26 ...
Page 46: ...3 8 Confirming Faulty Measurements 40 ...
Page 64: ...4 12 Compensating for Thermal EMF Offset Offset Voltage Compensation OVC 58 ...
Page 84: ...6 4 Auto Exporting Measured Values at End of Measurement Data Output Function 78 ...
Page 90: ...7 3 Printing 84 ...
Page 172: ...9 10 Device Compliance Statement 166 ...
Page 190: ...11 4 Disposing of the Instrument 184 ...
Page 200: ...Appendix 5 Dimensional Diagram A10 Appendix 5 Dimensional Diagram ...
Page 214: ...Index Index 4 ...
Page 215: ......
Page 216: ......
Page 217: ......
Page 218: ......