4. Power off the device.
5. Set the No.1 switches of the 8-digit DIP Switch on the main control board by referring to the
following figure.
6. Power on the device again.
Note
For details about the DIP switch value and meaning, see DIP Switch Description.
The barrier will open automatically and turns back to the closed position. At this circumstance,
the device enters the normal mode.
5.2 Pair Keyfob (Optional)
Pair the remote control to the device through DIP switch to open/close the barrier remotely.
Before You Start
Ask our technique supports or sales and purchase the keyfob.
Steps
Note
Up to 32 keyfobs can be added to the turnstile.
1. Power off the turnstile.
2. Set the No.4 switch of the DIP Switch on the access control board to the ON side.
3. Power on the turnstile and it will enter the keyfob pairing mode.
4. Hold the Close button for more than 10 seconds. Or pair turnstile and keyfob in the client
software, see Manage Keyfob User for more details.
The keyfob's indicator of the will flash twice if the pairing is completed.
5. Set the No.4 switch to OFF, and reboot the turnstile to take effect.
DS-K3B601SX Series Swing Barrier User Manual
29
Summary of Contents for DS-K3B601S Series
Page 1: ...DS K3B601SX Series Swing Barrier User Manual ...
Page 36: ...Figure 4 8 Interface and Corresponded UART No DS K3B601SX Series Swing Barrier User Manual 22 ...
Page 38: ...DS K3B601SX Series Swing Barrier User Manual 24 ...
Page 40: ...Entering Wiring Exiting Wiring DS K3B601SX Series Swing Barrier User Manual 26 ...