5. Parameter
Setting
5-7
5.2 Motor and System Parameter (Motor Parameter: P1--)
These parameters are used to set the motor and the system. User must set parameters to suit the
motor and the system prior to use.
Menu
Menu title
Description
Unit
Setting range
Default
*P1-01
Motor ID
Motor ID
0 ~ 99
0
ID
Model
ID
Model
ID
Model
ID
Model
ID
Model
0
Individual
input
20 TF05 40 LF03 60
KN03 80 LN03
1
21 TF09 41 LF06 61
KN05 81 LN06
2
22 TF13 42 LF09 62
KN06 82 LN09
3
23 TF20 43 LF12 63
KN07 83 LN12
4
24
TF30 44
LF20
64
KN06A
84
LN12A
5 CKZ5 25 TF44 45 LF30 65
KN11 85 LN20
6 CK01 26
TF09-05
46 66
KN16
86
LN30
7
27 47 67
KN22
87
LN40
8 CK02 28 48 68
KN22A
88
TN110
9 CK04 29 49 69
KN35
89
TN150
10
30 KF08 50
CN04A
70
TN05 90
11 CN01 31 KF10 51 CN06
71
TN09 91
12 CN02 32 KF15 52 CN08
72
TN13 92
13 CN03 33 KF20 53 CN10
73
TN17 93
14 CN04 34 KF35 54 CN09
74
TN20 94
15 CN05 35 KF50 55 CN15
75
TN30 95
16
36
56 CN22
76
TN44 96
17
37
57 CN30
77
TN75 97
18
38
58
CN30A
78
TN55 98
19
39
59 CN50
79
KN55 99
If the motor used is in the above table, input motor ID to [Motor ID(P1-01)].
In such case, [JM (P1-02)], [KT (P1-03)], [Ls(Phase) (P1-04)], [Rs(Phase) (P1-05)], [Is(Rated)
(P1-06)], [SPD(Max) (P1-07)], [SPD(Rated) (P1-08)], [Pole Number (P1-09)] among the set
values are automatically set, and individual editing is not allowed.
If the motor used is not shown on the above table, or if it is desired to change one or more of
the set values related to the motor, input 0 to [Motor ID (P1-01)].