Chapter 6. Operation Mode and How to use
6-
12
6.8 How to use Monitor
The servo's internal speed command and torque, and the feedback motor speed can be monitored
from outside through the analog output (MONIT1) and (MONIT2). The range of output voltage is -
4[V] - 4[V]. The following are the parameters related to the use of the motor
Menu
Menu name
Description
Unit
Range
Default
P2-10
Monitor1 Select
Set monitor 1
0-3
0
P2-14
Monitor2 Select
Set monitor 2
0-3
1
Set parameter to be output on the monitor
(0: position 1: position error, 2: speed 3:torque)
Menu
Menu name
Description
Unit
Range
Default
P2-11
Monitor1 ABS
Monitor1 mode
0,1
0
P2-15
Monitor2 ABS
Monitor2 mode
0,1
0
0: Output codes by type
1: Output absolute values
Menu
Menu name
Description
Unit
Range
Default
P2-12
Monitor1 Scale
Monitor1 magnification
multiple
1-20
1
P2-16
Monitor2 Scale
Monitor2 magnification
multiple
1-20
0
In case that observation in difficult because analog output value is small, it is to see that variable
multiply pertinent multiple.
For example, in case of input 3, variable size enlarges three times.
[Basis magnification] Position : 99999.9/4[V] ,
Speed : Maximum speed/4[V] &
torque : (3*rating torque)/4[V]
Menu
Menu name
Description
Unit
Range
Default
P2-13
Monitor1 offset
Monitor1 offset
%
-100-100
0
P2-17
Monitor2 offset
Monitor2 offset
%
-100-100
0
This is used to output values by applying appropriate offset to the analog output values. This is to
enable adjustment of the values output on 0[V] potential by applying offset to the monitor output.
Unit used is [%], and the maximum value is 100 [%]. If the speed is output assuming the
maximum speed as being 5000[rpm], 1000[rpm], 20[%] of 5,000, is displayed on 0[V] when offset
20 is loaded.
Monitor outputs according to the parameter set values are as follows. As the method of using
monitor 1 and monitor 2 is the same, the following figures show outputs of monitor 1 only.