10.3 Adjusting the ion blower
1
2
3
Fig. 40
1
2
3
4
Fig. 41
Ion blower
Lateral position
1
Ion blower
2
A quarter of the pile width
3
Pile width
1.
Loosen the tommy bar screw (Fig. 41/1).
2.
Adjust the ion blower to the format.
Position the ion blowers on the first quarter
(Fig. 40) of the sheet width on D.S. and O.S.
3.
Tighten the tommy bar screw (Fig. 41/1).
Height
4.
Use the knurled ring (Fig. 41/3) to adjust the
height of the ion blower.
The center of the ion blower (Fig. 41/4) must be
set to the level of the upper pile edge.
D
Rotating clockwise moves the ion blower
upwards.
D
Rotating anti-clockwise moves the ion
blower down.
Blast air volume
5.
The valve on the ion blower (Fig. 41/2) enables
you to adjust the blast air volume.
D
Vertical position: Full blast air volume.
D
Horizontal position: Blast air shut off.
The blast air volume can be set continuously.