GR FS9040000000000000
GR FS9040001000000000
Maintenance
confidential
D.3.5
3
Service activities on the suction head
3.1
Suction head
1
2
3
Fig. 2
Suction head
Place of installation
1
Lifting sucker
2
Forwarding sucker
3
Rotary valve
The suction head is installed above the feeder pile.
3.1.1
Lifting suckers Cleaning and checking
2
3
1
Fig. 3
Lifting sucker
1
Plate spring
2
Lifting sucker guide
3
Lifting sucker
Note
Do not lubricate!
Maintenance point description
Maintenance inter-
val
3 000 000 press rotations, or
monthly
Maintenance loca-
tion
D.S./O.S.
Accessing the main-
tenance point
See installation and removal.
Maintenance work
Clean and check 4 lifting
suckers.
Tool
Soft, fluffless cloth
Cleaning solution
See ”Approved cleaners”.
Tab. 2
UTKFS9040002000000000
UTKFS9040002000000000002