GR FS9040010000000000
GR FS904001
1000000000
Maintenance
confidential
D.3.13
5.3
Guide rail of the pile support plate
1
Fig. 14
Place of installation of the guide rail limit
switches
Place of installation
1
Guide rail limit switch
The guide rail and the limit switch of the pile board
are installed in the feeder.
5.3.1
Checking the limit switch
1
2
Fig. 15
Checking the function of the limit
switches
1
Guide rail
2
Limit switch
Maintenance point description
Maintenance inter-
val
15 000 000 prints, or twice a
year
Maintenance loca-
tion
Center
Accessibility of the
maintenance points
Remove the pile from the
feeder. Secure the press
against start-up.
Number/type/main-
tenance work
Check the limit switch func-
tion (safety test),
1st switching point: 120 mm
above the base,
2nd switching point: 12 mm
above the base.
Tool
–
Cleaning solution
–
Tab. 9