GR FS9040020000000000
GR FS9040021000000000
Maintenance
confidential
D.3.20
8.1.2
Replacing the filter cartridge ”suction air pull lay/propelling roller”
1
Fig. 26
Replacing the filter cartridges ”suction
air pull lay/propelling roller”
1
Filter cartridge ”suction air pull lay/propelling
roller”
Maintenance point description
Maintenance inter-
val
30 000 000 press rotations,
or yearly
Maintenance loca-
tion
D.S./middle
Accessing the main-
tenance point
Open the ”feeder” guard;
fold up the feed table; open
the service port.
Number/type/main-
tenance work
Replace 2 air filters.
Tool
–
Cleaning solution
–
Tab. 15
8.2
Rotary valve ”suction tape vacuum regulation”
2
1
3
Fig. 27
Rotary valve ”suction tape vacuum reg-
ulation”
Place of installation
1
Feeder table
2
Rotary valve ”suction tape vacuum regulation”
3
”Feeder” guard
The rotary valve ”suction tape vacuum regulation” is
installed in the middle, underneath the feed table.
UTKFS9040006000000000005
Summary of Contents for Speedmaster CD 102
Page 6: ...Main chapter overview A 2...
Page 20: ...Main chapter overview B 2...
Page 114: ...Preset Plus Feeder confidential C 1 76...
Page 118: ...Main chapter overview D 4...
Page 120: ...Chapter overview D 1 2...
Page 134: ...General information confidential D 1 16...
Page 136: ...Chapter overview D 2 2...
Page 146: ...Chapter overview D 3 2...
Page 166: ...Maintenance confidential D 3 22...