GR FS9040022000000000
GR FS9040023000000000
Maintenance
confidential
D.3.21
8.2.1
Cleaning the rotary valve ”suction tape vacuum regulation”
1
2
3
Fig. 28
Rotary valve ”suction tape vacuum reg-
ulation”; cleaning the valve ports
1
3
4
Fig. 29
Rotary valve ”suction tape vacuum reg-
ulation”; cleaning the surface
Cleaning valve ports, surface, and bearing
1
Rotary valve/surface
2
Valve ports
3
Cover plate
4
Bearing
Note
Do not lubricate!
Maintenance point description
Maintenance inter-
val
3 000 000 press rotations, or
monthly
Maintenance loca-
tion
Center
Accessing the main-
tenance point
Open the ”feeder” guard.
Fold up the feed table.
Number/type/main-
tenance work
Loosen and remove the
rotary valve. Clean valve
ports, surface and bearings.
Tool
Soft, fluffless cloth; brush
Cleaning solution
See ”Approved cleaners”.
Tab. 16
Caution – Damage
During any work on the rotary valve
you must ensuring that the surface is
not damaged.