GR FS9040030000000000
GR FS9040029000000000
Maintenance
confidential
D.3.16
3
1
4
2
Fig. 20
Suction tape – tolerance/adjustment
range
1
Suction tape
2
Mark – suction tape
3
Mark – feed table
4
Suction tape
Checking the suction tape tension
1.
Engage the feeder and move the suction tape
(Fig. 20/1) until the ”mark – suction tape”
(Fig. 19/2) on the ”reference” (Fig. 19/1) is
aligned with the ”mark–feed table” (Fig. 19/4).
2.
Check at the ”tolerance/adjustment range”
(Fig. 20/4), whether the ”mark – suction tape”
(Fig. 20/2) is between the ”marks – feed table”
(Fig. 20/3).
3.
If necessary, adjust the suction tape tension, or
replace the suction tape. Details can be found
in Chapter ”PresetPlus feeder” of the operating
manual.
6.2
Air filter ”suction tape suction air”
1
3
2
Fig. 21
Place of installation of the air filters
”suction tape suction air”
Place of installation
1
Air filter ”suction tape suction air”
2
Feeder table
3
”Feeder” guard
The two air filters are installed underneath the feed
table.
UTKFS9040007000000000005
Summary of Contents for Speedmaster CD 102
Page 6: ...Main chapter overview A 2...
Page 20: ...Main chapter overview B 2...
Page 114: ...Preset Plus Feeder confidential C 1 76...
Page 118: ...Main chapter overview D 4...
Page 120: ...Chapter overview D 1 2...
Page 134: ...General information confidential D 1 16...
Page 136: ...Chapter overview D 2 2...
Page 146: ...Chapter overview D 3 2...
Page 166: ...Maintenance confidential D 3 22...