D.3.10
Draining the condensation water
Caution –
The system pressure drops (approxi-
mately 6.1 bars ... 6.5 bars) when you
drain the condensate from the glass
cylinder. Never drain the glass cylinder
in ”production” or ”sheet travel” mode.
1.
Open the drain plug until a spray of condensa-
tion water emerges.
2.
Close the drain plug once the glass cylinder has
completely been drained.
3.
Check the manometer for a system pressure of
approximately 6 bars,or whether the pointer of
the manometer is in the green area.