![HEIDELBERG Speedmaster CD 102 Manual Download Page 66](http://html1.mh-extra.com/html/heidelberg/speedmaster-cd-102/speedmaster-cd-102_manual_2118608066.webp)
GR SG9015801000000000
GR SG9015802000000000
Preset Plus Feeder
confidential
C.1.28
8.2
Sheet separation blower
1
1
1
1
Fig. 31
Sheet separation blower
Adjusting the blast air
1.
Adjust the blast air volume of the sheet separa-
tion blowers (Fig. 31/1) on the control knob
(Fig. 29/6).
1
Fig. 32
Sheet separation blowers – adjusting
the height
Adjusting the height
1.
Adjust the height of the sheet separation blow-
ers with the knurled nut (Fig. 32/1). We recom-
mend to adjust the blast air such that 5 - 10
sheets are fanned.
8.3
Inner carrier air blowers
Adjusting the blast air
1.
Adjust the blast air of the inner carrier air blow-
ers at the control knob (Fig. 29/4).