APPENDIX
185
APS-003 Option
Output Voltage 0 ~ 600 Vrms
Model
APS-7050 APS-7100
APS-7200
APS-7300
Output
Power Rating
500VA
1000VA
2000VA
3000VA
Maximum current
(r.m.s)
*5
0 ~ 600Vrms
1.05 A
2.1 A
4.2 A
6.3 A
Maximum current
(peak) 0 ~ 600Vrms
4.2 A
8.4 A
16.8 A
25.2 A
Setting
Voltage
Range
0 ~ 155 Vrms, 0 ~ 310 Vrms, 0 ~ 600 Vrms, Auto
Resolution
0.01V at 0.00 ~ 99.99 Vrms
0.1V at 100.0 ~ 600.0 Vrms
Accuracy
*6
±
(0.5% of s 2 counts)
Measurement
*3
Voltage (r.m.s)
Range
0.2 ~ 600.0 Vrms
Resolution
0.01V at 0.00 ~ 99.99 Vrms
0.1V at 100.0 ~ 600.0 Vrms
Accuracy
±
(0.5% of r 2 counts)
APS-004 Option
Output Frequency 45 ~ 1000 Hz
Model
APS-7050 APS-7100
APS-7200
APS-7300
Setting
Frequency
Range
45.00 ~ 1000 Hz
Resolution
0.01 Hz at 45.00 ~ 99.99 Hz
0.1 Hz at 100.0 ~ 999.9 Hz
1 Hz at 1000 Hz
Accuracy
±
0.02% of Setting
Measurement
*3
Frequency
Range
45.00 ~ 1000 Hz
Resolution
0.01Hz at 45.00 ~ 99.99Hz
0.1Hz at 100.0 ~ 999.9Hz
1 Hz at 1000 Hz
Accuracy
0.1/1 Hz
Summary of Contents for APS-7000 Series
Page 1: ...Programmable AC Power Source APS 7000 Series USER MANUAL ISO 9001 CERTIFIED MANUFACTURER ...
Page 111: ...OPERATION 111 Simulate Example ...
Page 157: ...COMMUNICATION INTERFACE 157 Exit 6 Press Exit F4 to exit from the serial port settings ...
Page 187: ...APPENDIX 187 APS 7000 Dimensions APS 7050 402 545 5 430 110 4 87 9 Scale mm ...
Page 188: ...APS 7000 Series User Manual 188 APS 7100 561 6 705 5 430 110 4 87 9 Scale mm ...
Page 189: ...APPENDIX 189 APS 7200 402 5 310 5 429 8 682 4 649 2 Scale mm ...
Page 190: ...APS 7000 Series User Manual 190 APS 7300 491 5 399 5 429 8 682 4 649 2 Scale mm ...