REAR PANEL SIGNAL OUTPUTS
151
Wiring Schematic
Is5V
Trigger
Output
1k
COM
Trigger Input, OUT On/Off
330R
COM
Signal Output Overview
Overview
The Signal Output port is used in the Program
Mode. This port is used to remotely monitor the
PASS, FAIL and Processing conditions. Each of
these conditions are isolated from the APS-7000
with internal relays.
Pin Assignment
2
4
6
5
3
1
Remote relay contact
2
4
6
5
3
1
APS-7050
APS-7100
APS-7200
APS-7300
Pin name
Pin number
Description
1
Pass pin
2
Pass return pin
3
Processing pin
4
Fail pin
5
Processing return pin
6
Fail return pin
Pass: Connect between Pin1 and Pin2
Fail: Connect between Pin4 and Pin6
Processing: Connect between Pin3 and Pin5