Press the
Range
key repeatedly to set the
voltage range for the Vset parameter. The
Range will be shown in the top corner.
Range
Range
LO(155V), MD(310V), HI(600V,
optional), Auto
14.
Go to the
Vset
setting and set the output
voltage for the step. If the input setting voltage
doesn’t appear in the selected voltage range,
an “Over Range” alarm will appear during
Sequence. At this time, the output voltage
maintains on the previous setting voltage
value.
Vset
0 ~ 310V (range dependent)
(600V optional)
Secondary
settings
CT (Constant), KP (Keep), SP
(Sweep)
Note: Step 0 can only be set to CT
or SP.
Note
When output has been executed under Standard
Mode, press the [Test] key to enter Sequence Mode,
and then execute step 0 to set output value.
15.
Go to the
Fset
setting and set the frequency of
the step.
Fset
45.00 ~ 500.0Hz(1000Hz optional)