APPENDIX
183
Model
APS-7050
APS-7100
APS-7200
APS-7300
Accuracy
±
(0.6% of 5 counts),
2.00 ~ 350.0 mA
±
(0.5% of 5 counts),
0.350 ~ 3.500 A
±
(0.5% of 3 counts),
3.500 ~ 17.50 A
±
(0.5% of 5 counts),
0.200 ~ 3.500 A
±
(0.5% of 3 counts),
3.00 ~ 35.00 A
Current (peak)
Range
0.0 ~ 70.0 A
0.0 ~ 140.0 A
Resolution
0.1 A
0.1 A
Accuracy
±
(1% of r 1 count)
±
(1% of r 1 count)
Power (W)
Resolution
0.01 W
0.1 W
1 W
0.1 W
1 W
Accuracy
±
(0.6% of 5 counts),
0.20 ~ 99.99 W
±
(0.6% of 5 counts),
100.0 ~ 999.9 W
±
(0.6% of 2 counts),
1000 ~ 9999 W
±
(0.6% of 5 counts),
0.2 ~ 999.9 W
±
(0.6% of 2 counts),
1000 ~ 9999 W
Apparent Power
(VA)
Resolution
0.01 VA
0.1 VA
1 VA
0.1 VA
1 VA
Accuracy
±
(1% of r 7 counts),
0.20 ~ 99.99 VA
±
(1% of r 7 counts),
100.0 ~ 999.9 VA
±
(1% of r 5 counts),
1000 ~ 9999 VA
±
(1% of r 7 counts),
0.2 ~ 999.9 VA
±
(1% of r 5 counts),
1000 ~ 9999 VA
Power Factor
Resolution
0.001
Accuracy
±
2% r 2 counts
Summary of Contents for APS-7000 Series
Page 1: ...Programmable AC Power Source APS 7000 Series USER MANUAL ISO 9001 CERTIFIED MANUFACTURER ...
Page 111: ...OPERATION 111 Simulate Example ...
Page 157: ...COMMUNICATION INTERFACE 157 Exit 6 Press Exit F4 to exit from the serial port settings ...
Page 187: ...APPENDIX 187 APS 7000 Dimensions APS 7050 402 545 5 430 110 4 87 9 Scale mm ...
Page 188: ...APS 7000 Series User Manual 188 APS 7100 561 6 705 5 430 110 4 87 9 Scale mm ...
Page 189: ...APPENDIX 189 APS 7200 402 5 310 5 429 8 682 4 649 2 Scale mm ...
Page 190: ...APS 7000 Series User Manual 190 APS 7300 491 5 399 5 429 8 682 4 649 2 Scale mm ...