OPERATION
143
System
Configuration
Screen Overview
Test mode
System Conf
Save/Recall
Run test
Contrast
Loop
Timer Unit
Alarm
Single Step
Run Mode
V-limit
F-limit
Phase
Power Up
Results
Surge Dip
OC Fold
System
Configuration
Parameters
The System Configuration screen is accessible
when the
System Config[F2]
soft-key is pressed.
Run Mode
When set to “MANUAL” mode, only
Memory number, VSET, FSET, H-
IRMS(A), SD-VOLT, SD-SITE,
SD_CONT and SD-TIME will be
enabled.
When set to “PROGRAM” mode, all
the parameters are available.
Single Step Sets the program to run only one
step at a time. After a step is run
the program is held until the
Output key is pressed, after which
the program will go to the next step.
Alarm
Turns the alarm buzzer on/off.
Power Up
When this option is turned on, the
current program will be loaded and
run after APS-7000 powers up.