2-44
2.13.1 Setting Page Length (Simple mode)
Use 1 Page Length when usng Roll meda.
If the machne receves data for a cut longer than the set page length, t wll only cut for the set area parameters.
The excess area wll not be cut.
Ths can also be set n Normal mode.
Reference
Default page length s 3 m. When dong long cuts, set the page length. Check the settng of the page length when cuttng long length.
* Be sure to use the basket.
For the CE6000-120AP, the page length up to 50 m can be set. We gve qualty assurance for page feedng up to 3 m. (Under the
condton that the meda descrbed below s used.)
• Be sure to use the basket.
• Meda: genune Graphtec brand products
• Settng Condtons: Speed under 30, acceleraton under 2.
• Perform pre feed for the amount to be used before cuttng.
• Leave the meda n envronment to use for adequate tme f the devaton of temperature and humdty s bg.
• Set the both push rollers at least 15mm nsde the edge of meda.
• The paper needs to be reset after cuttng 5 consecutve pages.
• Each page should be removed from the basket after t has been cut.
When settng meda for long-plottng, set the tenson on the left and rght of the wdth of the meda to a unform value. If t s not
unform, the meda may be removed from the roller that presses t durng plottng.
Make sure to level the whole of the meda to get rd of unevenness before cuttng. (See "Settng the number of pre feeds"
P.4-7
).
Also, pre feedng can be done automatcally when the data s receved (see "Perform Automatc Pre Feed When Cut Data s
Receved"
P.7-4
), or done automatcally when the meda s loaded (see "Perform Automatc Pre Feed When Meda s Set (Intal
Feed)"
P.7-6
).
* Pre feeding will stabilize the feed by acclimating the media, taking out the slack.
Ths settng s mantaned even after the power s turned off.
Operation
1
Press [PAUSE/MENU] key.
MENU screen s dsplayed.
2
Press [1] key (MEDIA).
MEDIA SETTING screen s dsplayed.
3
Press [2] key (PAGE LENGTH).
PAGE LENGTH screen s dsplayed.