A-12
Menu items
Setting items
Initial value
ADVANCE
MOVE STEP
0.1 mm
LANGUAGE SELECTION
Select when ntally turnng on power
LENGTH UNIT
Select when ntally turnng on power
MEDIA SENSOR
ENABLED
PUSH ROLLER SENSOR
ENABLED
FAN POWER
NORMAL
BEEP FOR KEY OPE.
ON
TEST
NO SETTINGS
–
TOOL
SETTING
CONDITION NO. 1
TOOL CONDITION NO.
CONDITION NO. 1
TOOL
PEN
SPEED
30
FORCE
12
ACCELERATION
2
CUT LINE PATTERN
OFF
TANGENTIAL MODE
OFF
OVERCUT (START)
0.000
OVERCUT (END)
0.000
DISTANCE ADJUST
OFF
INITIAL DOWN FORCE
0
SET BLADE GROUP
1
SET FACTOR
1.0
CONDITION NO. 2
TOOL CONDITION NO.
CONDITION NO. 2
TOOL
CB09U
SPEED/FORCE/ACCELERATION
30//8/2
CUT LINE PATTERN
5
TANGENTIAL MODE
OFF
OVERCUT (START)
0.200
OVERCUT (END)
0.200
DISTANCE ADJUST
OFF
INITIAL DOWN FORCE
0
SET BLADE GROUP
2
SET FACTOR
1.0
CONDITION NO. 3
TOOL CONDITION NO.
CONDITION NO. 3
TOOL
CB09U
SPEED/FORCE/ACCELERATION
30/14/2
CUT LINE PATTERN
3
The range between tangential mode and wear degree (coefficient)is same as Condition 2
CONDITION NO. 4
TOOL CONDITION NO.
CONDITION NO. 4
TOOL
CB09U
SPEED/FORCE/ACCELERATION
20/6/2
CUT LINE PATTERN
1
The range between tangential mode and wear degree (coefficient)is same as Condition 2
CONDITION NO. 5
TOOL CONDITION NO.
CONDITION NO. 5
TOOL
CB09U
SPEED/FORCE/ACCELERATION
20/8/2
CUT LINE PATTERN
4
The range between tangential mode and wear degree (coefficient)is same as Condition 2
CONDITION NO. 6
TOOL CONDITION NO.
CONDITION NO. 6
TOOL
CB15U
SPEED/FORCE/ACCELERATION
30/16/2
CUT LINE PATTERN
3
The range between tangential mode and wear degree (coefficient)is same as Condition 2
CONDITION NO. 7
TOOL CONDITION NO.
CONDITION NO. 7
TOOL
CB15U
SPEED/FORCE/ACCELERATION
20/12/2
CUT LINE PATTERN
3
The range between tangential mode and wear degree (coefficient)is same as Condition 2
CONDITION NO. 8
TOOL CONDITION NO.
CONDITION NO. 8
TOOL
CB09U
SPEED/FORCE/ACCELERATION
30/8/2
CUT LINE PATTERN
User
The range between tangential mode and wear degree (coefficient)is same as Condition 2
* The ntal values of settng tems s subject to change.